नॉर्डेन-लोगो

नॉर्डन NFA-T01LM लूप एक्सटेंशन मॉड्यूल

NORDEN-NFA-T01LM-Loop-Extension-Module-fig-1

उत्पाद की जानकारी

विशेष विवरण

  • अनुपालन: EN 54 Part 18 (European Standard)
  • इनपुट वॉल्यूमtage: डीसी24वी
  • Bus Input Range: 1000मी

उत्पाद उपयोग निर्देश

इंस्टालेशन

  • स्थापना की तैयारी
    This interface module must be installed, commissioned, and maintained by qualified or factory-trained service personnel. Ensure compliance with all local codes in your area or standards like BS 5839 Part 1 and EN54.
  • स्थापना और वायरिंग
    1. Install the loop extension module where anti-interference is needed or for extending bus communication distance within 1000m.
    2. Securely fix the module with screws in a suitable location.
    3. Refer to the external wiring terminal diagram for proper wiring.

Loop Extension Module Configuration

  • Outline Dimension Chart
    Refer to the outline dimension chart for the physical size of the loop extension module.
  • काम के सिद्धांत
    The loop extension module collects bus signals, processes them through the MCU to output a standard bus waveform. The signal isolation circuit extends the bus communication distance and corrects the bus waveform through an optocoupler.

अस्वीकरण 
सर्वाधिकार सुरक्षित।
इस दस्तावेज़ में दी गई जानकारी बिना किसी सूचना के बदली जा सकती है

उत्पाद सुरक्षा 
गंभीर चोट और जान-माल की हानि को रोकने के लिए, सिस्टम का उचित और सुरक्षित संचालन सुनिश्चित करने के लिए डिटेक्टर स्थापित करने से पहले निर्देशों को ध्यानपूर्वक पढ़ें।

परिचय

ऊपरview

  • NFA-T01LM लूप एक्सटेंशन मॉड्यूल एक DC24V पावर सप्लाई पर काम करता है और एक आंतरिक विद्युत आइसोलेशन सर्किट का उपयोग करके इनपुट और आउटपुट बस सिग्नलों का रीयल-टाइम आइसोलेशन और ट्रांसमिशन प्राप्त करता है, जिससे एक मानक बस वेवफ़ॉर्म प्राप्त होता है। यह मॉड्यूल बस के हस्तक्षेप के प्रतिरोध को बढ़ाता है और संचार सीमा का विस्तार करने में मदद करता है। यह उन वातावरणों में विशेष रूप से प्रभावी है जहाँ बाहरी हस्तक्षेप होता है या जहाँ लंबी संचार दूरी की आवश्यकता होती है।
  • EN 54 भाग 18 (यूरोपीय मानक) के अनुरूप, इस इकाई का डिज़ाइन आधुनिक इमारतों के लिए उपयुक्त है। इसकी प्लग-इन असेंबली आसान स्थापना और रखरखाव की सुविधा देती है। NFA-T04FP इंटेलिजेंट एड्रेसेबल फायर अलार्म कंट्रोल पैनल के साथ पूरी तरह से संगत, यह संगतता संबंधी समस्याओं के बिना निर्बाध एड्रेसेबल संचार सुनिश्चित करता है।

विशेषताएं एवं लाभ

  • EN54-18 अनुपालन
  • Built-in MCU processor
  • Input bus, the output bus signal between the electrical isolation, electromagnetic interference has a good inhibitory capacity, stable and reliable work. Input Fire or Supervisory signal configuration.
  • एलईडी स्थिति सूचक
  • To correct the bus signal, the output standard bus waveform
  • Fast intelligent bus output short circuit judge function, bus output short circuit protection function; after the bus is normal, it can recover the bus output in time
  • सौंदर्य की दृष्टि से मनभावन डिजाइन

तकनीकी निर्देश 

अनुपालन एन 54-18:2005
इनपुट वॉल्यूमtage Loop Power:24VDC [16V to 28V]

External PSU: 20 to 28VDC

वर्तमान खपत Loop: ≤5mA

External PSU: ≤500mA

Bus input range: ≤1000m Bus output range: ≤1000m
Most cascade तीन
Protocol/Addressing Norden, Value ranges from 1 to 254
संकेतक स्थिति Normal: Single blink/Fault: Steady-on
Material / Colour Metal / Gray
Dimension / LWH 155.0मिमी×97.0मिमी×40.0मिमी
परिचालन तापमान -10°C से +55°C
नमी 0 to 95% Relative Humidity, Non-condensing

इंस्टालेशन

स्थापना की तैयारी
This interface module must be installed, commissioned, and maintained by a qualified or factory-trained service personnel. The installation must be installed in compliance with all local codes having jurisdiction in your area, or BS 5839 Part 1 and EN54.

स्थापना और वायरिंग

  1. The loop extension module is used for anti-interference. When used outside the site should be installed in the presence of disturbances, such as the shielding effect of the iron shell. , extension module as an extended bus communication distanc, is used; it should be installed at the output end of long long-distance bus controller within 1000m; fixed by screws, installed in the room.
  2. The external wiring terminal diagram is shown below:

    NORDEN-NFA-T01LM-Loop-Extension-Module-fig-1

    • डी1, डी2: 24V पावर इनपुट टर्मिनल
    • I1, I2: Bus input terminal
    • 01, 02: Bus output terminal, 01 is the positive, 02 is the negative.
    • तारों की आवश्यकताएँ: no polarity signal, two buses using RVS twisted pair,
    • Sectional area≥1.0mm²;
    • DC24V power using BV line, Sectional area≥1.5mm²
      NOTE: The NFA-T01LM cannot be used in the loop.

Loop extension module configuration

Outline dimension chart

NORDEN-NFA-T01LM-Loop-Extension-Module-fig-3

काम के सिद्धांत
The loop extension module collects the bus signal through the bus transceiver circuit, and outputs the control bus output circuit after the MCU processes the standard bus waveform; the signal isolation circuit bus input and output through an optocoupler can extend the bus communication distance and can correct the bus waveform.

उपयोग और संचालन

  1. The use of the loop extension module must follow the following requirements:
    Meet the technical parameters defined in this specification
  2. After the loop extension module is installed, or in the use of the process to be tested every six months, the test method is as follows:
    1. The fire alarm controller is used to connect the front-end coding device with the extension module, and the coding equipment should be able to log in correctly.
    2. The detector, which is connected to the bus through the extension module is reports to the fire alarm, and the controller should be able to receive the alarm information correctly.

हैंडलिंग और भंडारण
Transport, storage, and handling equipment shall be carried out in a packing condition. Loading and unloadprocessescess must be handled with care to prevent collision damage. StorageThehe environment shouldmaintainedn ventilation, dry, and avoid open storage.

सामान्य रखरखाव

  • रखरखाव करने से पहले उपयुक्त कार्मिक को सूचित करें।
  • Disable the loop extension module on the control panel to prevent false alarms.
  • Do not attempt to repair the circuitry of the loop extension module; it may affect the operation to respond to a fire condition and will void the manufacturer’s warranty.
  • Notify again proper personnel after conducting the maintenance, and make sure to enable the loop extension module and confirm if up and running.
  • Perform the maintenance semiannually or depending on the site conditions.

मुख्य विचार

  • On-duty personnel should be familiar with the operation of the equipment, not the wrong operation.
  • This module for fire protection products must strictly implement the duty system and the shift in use, and make a running record.
  • Not every half a year is a function of the module test.

परिशिष्ट 1

Limitations of the Loop extension module

  • The loop extension module cannot last forever. To keep the loop extension module working in good condition, please maintain the equipment continuously according to recommendations from manufacturers and relevant national codes and laws. Take specific maintenance measures based on different environments.
  • This loop extension module contains electronic parts. Even though it is made to last for a long period of time, any of these parts could fail at any time. Therefore, test your module at least every half-year according to national codes or laws. Any loop extension module, fire alarm devices, or any other components of the system must be repaired and/or replaced immediately as they fail.

कंपनी के बारे में

अक्सर पूछे जाने वाले प्रश्नों

इनपुट वॉल्यूम क्या है?tagNFA-T01LM लूप एक्सटेंशन मॉड्यूल के लिए क्या आवश्यकता है?

The module operates on a DC24V power supply.

How far can the bus input range of the module extend?

The bus input range can extend up to 1000m.

दस्तावेज़ / संसाधन